The New “Quick-Release Vacuum System”® is an innovative design allowing the user to easily remove the vacuum system and seal bar for simplified cleaning, sterilization and maintenance. The new vacuum and seal bar design accommodates a pouch with as little as 1” header space.
The New linear element tensioner has no exposed electrical connections, won’t allow binding and assures element tension under all pressure settings. The new design simplifies element replacement and extends element life.
8000 Series Features
Full Digital, High-Speed, PLC Controller with Color enhanced LCD Touch screen HMI.
Password protected digital control of:
- All Seal parameters; temperature, time, pressure
- Process Recipes
- Alarm Settings
- Calibration Screens
Multiple Operating Modes:
5 Selectable modes:
- Gas-Vac-Seal (1-99 cycles)
- Vac-Seal
- Seal Only
- Vac-Gas-Vac-Seal
- Vac-Gas-Seal (1-99 Cycles)
“Quick-Release Vacuum System”®
- Easily Release the Vacuum and seal bar(s) for cleaning, sterilization and maintenance
Visible and Audible Alarms:
- Cold Seal Temperature Profile
- Jaw Obstruction
- Seal Temperature with Settable High & Low Alarms
- Seal Pressure with Settable High and Low Alarms
NEMA 4X Stainless Steel Enclosure:
- Laser cut and welded seams allow for cleaning and resists the effects of harsh biocides
Gas Purge Standard
High-Flow, Retracting Vacuum Nozzle
Upper and Lower Heating elements
High Pressure Seal Jaws with Guided Cylinder
Linear Element Tensioner:
- New Element Tension Design Eliminates Hot Ends
- Reduces Element Buckling
- Easier to Maintenance
External Verification Ports for Calibration of:
- Seal Temperature
- Seal Time
- Seal Pressure
- Gas Pressure
Electronic Footswitch Activator
Safety Features
Emergency Stop
Safe Low Pressure Jaw Close
Internal ‘coyote’ high temperature limit
Thermal overload protection
CLEANROOM FEATURES
Non-Particle generating Venturi Vacuum System
Isolated Exhaust Port
Clean Design to Class 100
Disposable vacuum line from nozzle to filter
OPTIONS
Multiple Vacuum Nozzles (varies by bag and carrier plate size)
Vacuum Particle Filter
Vacuum Moisture/ liquid Filter
Exhaust Silencer
220VAC Conversion
CE Certification
Initial Calibration